Performanceance:
Excellent short and long term stability are found in our QuickTrace® M-7600 CVAA analyzer. Less than 0.3 ng/L instrument detection limits are typical for this analyzer while utilizing less than 4 minutes of sample time and less than 25 mL of sample.
|
 |
Ultra-trace detection limits (< 0.5 ng/L IDL) |
 |
Linearity greater than 4 orders of magnitude |
 |
Dynamic range < 0.5 ng/L to > 500 μg/L |
 |
Without employing our smart rinse technology the system is ready to accurately measure a sample within four minutes following the ingestion of a 1 mg/L sample |
 |
Short term precision (%RSD @ 95% Confidence) < 1.2% @ 20 ng/L, n=5 |
 |
Short term precision (%RSD @ 95% Confidence) < 6.0% @ 5 ng/L, n=5 |
Key Features: |
 |
Compatible with EPA methods such as EPA Method 245.1, 245.5, 245.7, SW 846-7470 and SW 846-7471 |
 |
Patented non-foaming gas liquid separator (GLS) |
 |
TCP/IP communications per your laboratories preferences |
 |
GLS overflow prevention system |
 |
Detector saturation prevention combined with Smart Rinse - prevents carryover from high concentration samples |
 |
Patented double beam optics for superior baseline stability |
 |
Ozone free low vapor pressure mercury excitation lamp thermally stabilized with feedback control |
 |
Smart rack technology |
 |
Filtered charge-coupled device (CCD) system |
 |
Full computer control of instrument parameters |
 |
Maintenance free Nafion® dryer |
 |
Internal universal switching power supplies |
 |
Analyze samples with or without assistance of an autosampler |
 |
Optional autosamplers (Manual - no autosampler, ASX-260, ASX-520), autosamplers combined with powerful customizable software can process up to 10 standard/QC solutions and 84 50 mL sample/QC solutions in a single unattended run. We do not limit the number of QC samples or positions |
 |
Full computer control of autosampler rinse pump |
 |
Unlimited QC sample positions |
 |
Automatic end of run standby routines |
 |
Powder coated metal construction |
 |
12 roller 4 channel peristaltic pump |
 |
Sample volume 0.5 mL to > 20 mL |
 |
High capacity mode of < 60 seconds per sample |
 |
Intuitive QuickTrace™ software with built-in calibration, report generation and quality control features designed to make EPA compliance simple |
QuickTrace™ M-7600 Mercury Analyzer Specifications: |
 |
Argon or nitrogen carrier gas supplied at 120 psi |
 |
Power Requirements: 100-240 VAC +/- 10%, 50/60 Hz |
 |
Dimensions (H x W x D): 46 x 20 x 56 cm |
 |
Weight: 16 kg (35 lbs) |
 |
Computer Interfaces: Ethernet |